In Miami Dade, all pool enclosures designs need to be able to support wind loads of 170 MPH Exposure “C” category II. In Broward and Palm Beach Counties, the requirements are 165 MPH. These construction wind loads for screen enclosures were implemented after hurricane Andrew and updated in 2010 to ensure all new aluminum enclosures have a better chance of withstanding hurricane wind forces.

Screen Pool Enclosures Design & Engineering

k bracing
K-Bracing Connection
colum beam
Beam to Column Connection

In addition, a perimeter footing is required. In most cases, an 8″x 8″ will comply if the new footing is connected off the existing concrete deck. There may be requirements for a larger footing when there is no existing deck to attach the footing (for example a “paver area”).   

 

 

 

Nylo Tec Hardware

Alumicenter Inc. is now offering new superior connection fasteners that not only will ensure a nicer finish but are long lasting fasteners that will not rust. Call to get more information.….

 

 